RS-232 cable pin out for sartorius balances
Precision Weighing Balances
Home > Sartorius > Sartorius Balances using HyperTerminal Sartorius Balances

Balances Search:

NEW USB interface

Entire Sartorius Line

Cross reference an
old model with new

Micro (1-0.1µg)
SE/ME Series
LE26P Balance
CP2P Series

Analytical (0.1-0.01mg)
Genius - Pro
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
GC - Gem
TE - Economy

Milligram (0.001g)
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
GW - Gem
GC - Gem

Precision (0.01-0.1g)
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
GW - Gem
GP - Gem

Legal for Trade
Diamond Scale
Pharmacy Scale

Portable (0.1-0.001g)
TE Series
GE - Gem
ELT Series

High Cap (16kg-64kg)
LE - isoCAL
LA - Pro
CP - Standard

Moisture Analyzers
MA Professional
MA - Standard
MA - Economy

Explosion-proof
FC-Ex Series

Bench Scales
EA/EB Scales

Filter Balances
SE2F 2g x 0.1ug
ME5-F 5g x 1ug
CP2P-F 2g x 5ug
LA130S-F x 0.1mg

Industrial Scales
QC Washdown
Floor Scales

Mass Comparators
21g 0.001mg
10kg x 0.01mg
303kg x 1g
3,000kg x 10g

Used / Demo Units
Micro Balances
Analyticals

Accessories
Cal Weights
Mass Sets
Certified Weights
Specific Gravity
Printer
Static Eliminator
Winwedge Software
Weigh Dishes
Weigh Boats
Beakers
Titration Cups
Moisture Pans
Glassine Paper
AL Dishes
Weighing Canoes

Manufacturers
Acculab
AdamLab
Cas
Chatillon
Dillon
Health-o-Meter
Mettler Toledo
My-weigh
Ohaus
Other Brands
Salter Brecknell
Sartorius
Scientech
SECA Medical
Siltec
Tanita
Used

VMC
Weigh South


usb digital scales



Using WinCT Balance Software Wedge if you own both a Sartorius and A&D Balance. 
Please note WinCT is shareware and was designed with A&D Balances and no technical support is offered in using the software with a Sartorius Balance.  We are only highlighting how a person that purchased an A&D balance like the A&D GH-252 and using WinCT have also had succeeded using RSKey with their Sartorius Balance.

Some of our clients that own A&D and Sartorius Balances have successfully used A&D's shareware data communication software called WinCT using the RsKey program to import data from the balance into Excel or MS Word.  To accomplish this go to www.balances.com/and/rskey.html and in the first paragraph is a link to "download WinCT".

Load WinCT on your PC.

use just the RSKey software.

Set the software to

Com Port 1 "typically 1 for RS-232, 3 or 4 for USB" but check your computer manual
Baud 1200
Parity odd
Length 7
Stop 1
Terminator CR/LF

and bingo data goes from your balance to your computer into MS Word, Excel or Access.

Remember you can always use HyperTerminal and this is the most basic data acquisition program and it is probably already loaded on your computer now.


Below are some example how you can configure RSKey to import the scale's data output into Microsoft Excel.
If you select All from the "Type" drop down box WinCT will import the weight on the scale along with the mass unit.  In the above example "N" is for net weight, "+" for a positive weight, the weight "0.0840" and the mass unit is "ozt" for troy ounces.

Checking the Time check box results in the pc system clock to show the time the reading was acquired.

Checking the Date check box results in the pc system clock to show the date the reading was acquired.
 
If you select Numbers from the "Type" drop down box WinCT will import only the weight on the scale and ignores the mass unit.  In the above example just 0.1505 is imported to the spreadsheet.

Checking the Time check box results in the pc system clock to show the time the reading was acquired.

Checking the Date check box results in the pc system clock to show the date the reading was acquired.
If you select Numbers from the "Type" drop down box WinCT will import only the weight on the scale and ignores the mass unit.  In the above example just 0.1505 is imported to the spreadsheet.

Leaving the Time check box Unchecked results in the WinCT Software to ignore recording the time the reading was acquired.

Leaving the Date check box Unchecked results in the WinCT Software to ignore recording the date the reading was acquired.
If you select All from the "Type" drop down box WinCT will import the weight on the scale along with the mass unit.  In the above example "N" is for net weight, "+" for a positive weight, the weight "0.0840" and the mass unit is "ozt" for troy ounces.

Leaving the Time check box Unchecked results in the WinCT Software to ignore recording the time the reading was acquired.

Leaving the Date check box Unchecked results in the WinCT Software to ignore recording the date the reading was acquired.
sartorius electronic balanceusb interface balance

Hot Buys | Analytical Balances | Baby Scales | Counting Scales | Industrial Platform & Bench Scales | Mechanical Balances
Moisture Balances | Pocket Scales | Portable Balances | Precision Toploader Balances | Price Computing Scales | Bodyfat Scales
Contact Us | Return Policy | Home | Sitemap

Have Questions? Call 978-521-7095 or e-mail us your questions and we will assist you in your selection.