balance communication scale weighRS-232 cable pin out for sartorius balances
Precision Weighing Balances
Home > Sartorius > Sartorius Balances using HyperTerminal Sartorius Balances

Balances Search:

Cross reference an
old model with new

Mettler > Sartorius

Entire Sartorius Line

Micro (1-0.1µg)
Cubis Series
ME36-S Balance
CPA26P Balance
SE/ME Series
LE26P Balance
CP2P Series

Analytical (0.1-0.01mg)
Entris Balances
Practum Scales
Quintix Balances
Secura Scales
Cubis Series
Genius - Pro
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
AZ - Basic
GC - Gem
TE - Economy

Milligram (0.001g)
Entris Scales
Practum Balances
Quintix Scales
Secura Balances
Cubis Series
LE - isoCAL

LA - Pro
CP - Standard
ED - Extend
GK - Gem
AZ - Basic
BL Scales
TE - Economy
AY123 Scale
GC - Gem

Precision (0.01-0.1g)
Entris Balance
Practum Scale
Quintix Balance
Secura Scale
Cubis Series
LE - isoCAL

LA - Pro
CP - Standard
ED - Extend
AZ - Basic
TE - Economy
BL Portable
AY Scales
GW - Gem
GP - Gem

Legal for Trade
Diamond Scale
Pharmacy Scale

Portable (0.1-0.001g)
TE - Economy
GE - Gem
ELT Series
AY Scales

High Cap (16kg-64kg)
LE - isoCAL
LA - Pro
CP - Standard

Moisture Analyzers
MA160
MA37
MA100/MA50
MA150
MA35

Explosion-proof
FC-Ex Series

Bench Scales
Signum Scales
Midrics Scales
EA/EB Scales

Filter Balances
MSA2.7S x 0.1ug
MSA6.6 x 1ug
Quintix65 x 10ug
SE2F 2g x 0.1ug

ME5-F 5g x 1ug
CP2P-F 2g x 5ug
LA130S-F x 0.1mg

Industrial Scales
QC Washdown
Floor Scales

Mass Comparators
21g 0.001mg
10kg x 0.01mg
303kg x 1g
3,000kg x 10g

Used / Demo Units
Micro Balances
Analyticals

Accessories
Cal Weights
Mass Sets
Certified Weights
Specific Gravity
Printer
Static Eliminator
Winwedge Software
Weigh Dishes
Weigh Boats
Beakers
Titration Cups
Moisture Pans
Glassine Paper
AL Dishes
Weighing Canoes
Micro Dishes

Manufacturers
AdamLab
AND Weighing
CAS Scales
Chatillon
Health-o-Meter
Mettler Toledo
My-weigh
Ohaus
Sartorius
Scientech
SECA Medical
Troemner
Siltec
Tanita
Weigh South


HyperTerminal is a serial communication program provided in the Windows 98SE/ME/2000 and XP operating systems.  You can use HyperTerminal to communicate with any balance equipped with an RS-232 serial interface or USB.  HyperTerminal will receive the data output from the balance and display the information on the monitor screen of HyperTerminal program.

To setup HyperTerminal to communicate with a Sartorius Balance using the USB to Serial Adapter kit for Sartorius Balances (Sartorius YCC01-USBM2 USB Cable) follow the steps below.

HyperTerminal will help you create a clickable icon.  A series of screens will appear when Hypertrm.exe is clicked allowing you to configure settings.

Step 1

You start HyperTerminal by clicking Start, pointing to Programs, pointing to Accessories, pointing to Communications, and the click HyperTerminal.
  usb digital scales
  [ Click for pop-up window showing close-up view ]
     
Step 2

After a few moments the Connection description window will appear.  Enter a valid name, such as "Sartorius", into the Name: field, the Icon: field can remain at default.  Click OK when finished.
  sartorius balances
  [ Click for pop-up window showing close-up view ]
     
Step 3

The next screen is the Connect To window.  Enter the COM port number you are using into the Connect using : field.  The bottom pull down allows you select from Direct to Com1, Direct to Com2, Direct to Com3 or Direct to Com4.  The most common selections are Direct to Com3, or Direct to Com4.  The Country Code: , Area code: and Phone Number: fields can remain at default.  Click OK when finished.

Note: The most common problem resulting in data not transferring to HyperTerminal is selecting the wrong Com Port.  If Com3 does not work then try Com4
  balance interface
  [ Click for pop-up window showing close-up view ]
     
Step 4

The next screen is the Properties window.  Enter the baud rate into the Bits per second: field.  The top pull down typically allows you to select from the available bit rates.  The Sartorius default format is 1200.  The data bits: Odd, Stop bits: 1, and Flow control: None.  Click OK when finished.

Note: If the Baud rate, Data bits, Parity or Stop bits are not set correctly then HyperTerminal will not work.  Be careful and select the correct setting.
  usb balance
  [ Click for pop-up window showing close-up view ]
     
Step 5

In the following HyperTerminal window click on Files then on Properties then on Settings then on ASCII setup.  Put a check mark in the box marked Append line feeds to incoming line ends.  Click OK when finished and then Click OK again so you are back in the HyperTerminal window.

The Close the HyperTerminal window and say Yes to disconnect now and Yes to Save HyperTerminal session when prompted to Sartorius balance.

Now you're ready to use HyperTerminal

  1. Start your data acquisition by clicking Start, pointing to Programs, pointing to Accessories, pointing to Communications, clicking HyperTerminal, and then clicking on the Sartorius balance icon in our example.
  2. Connect the Sartorius Balance to your PC's USB Port with our USB to Serial Adapter cable (our part # SARUSB) and then apply power to the balance.
  3. Press the "Print" key on the Sartorius balance and weight shown on the display of the balance also shows in the HyperTerminal screen.
  4. For information about how to use HyperTerminal, click the Help menu in HyperTerminal .
  rs232 balance

[ Click for pop-up window showing close-up view ]
     
sartorius electronic balanceusb interface balance

Hot Buys | Analytical Balances | Baby Scales | Counting Scales | Industrial Platform & Bench Scales | Mechanical Balances
Moisture Balances | Pocket Scales | Portable Balances | Precision Toploader Balances | Price Computing Scales
Contact Us | Return Policy | Home | Calibration Weights | Sitemap

Have Questions? Call 978-521-7095 or e-mail us your questions and we will assist you in your selection.